17 / Aug / 2026

The job of a booster pump is to increase the pressure of water that is already flowing in the pipes or in tanks to ensure the pressure is adequate in all outlets. In high-rise buildings, villas, and plants, the pressure in the main pipes or in tanks does not suffice at higher levels or at the end of long pipelines.

Most booster pumps for buildings and industries are multistage centrifugal pumps, typically more than one pump mounted in a skid along with a controller. This guide will help understand why pressure drop occurs, sizing of a booster pump in terms of head and flow, importance of variable speed controls, and Xylem Goulds multistage pumps offered by GENAVCO.

The Reason Behind Reduced Water Pressure in Upper Floors

Height gained means loss of water pressure. By way of estimation, an increase of 10 meters reduces water pressure by one bar. On average, a floor is from 3 to 3.5 meters high, which means that a building loses one bar of water pressure for every 3 floors even without the effect of pipe resistance. Shower, mix valve and other appliances like hot water heater and RO unit have certain minimal pressure requirements; therefore, it is the top floors that experience problems first.

Water demand fluctuates during the day. A booster set has to hold pressure steady across that swing, not just at one design point.

How a Booster Pump Is Sized

  • Height: The static height above the pump to the highest delivery point, together with frictional loss, plus the head requirement at the highest delivery point. It should be expressed in metres of water.
  • Discharge: the maximum rate of flow measured in cubic metres per hour or litres per second, depending on the maximum number and types of connections that operate simultaneously.
  • Duty & Standby: Vital structures keep one pump always available for standby to ensure there is always water even when repairs are needed.
  • Control: Fixed speed and start-stop pumps, or variable speed pumps maintaining a constant pressure.

Why Multistage Pumps Are Used for Boosting

A centrifugal stage adds a certain amount of pressure. A multistage pump stacks several stages on one shaft, so each adds to the last and the pump reaches high head without a very large impeller or very high speed. That makes multistage pumps compact, efficient at boosting duties, and easy to match to a building's height by choosing the number of stages.

Fixed Speed vs Variable Speed Booster Pumps

Factor Fixed-speed booster Variable speed booster
Pressure at outlets Rises and falls as pumps cut in and out Held close to a set point
Energy use at low demand Pump runs at full speed when on Pump slows down to match demand
Wear on pumps and pipework More starts and pressure surges Softer starts and steadier running
Best for Simple, steady demand Buildings and plants with demand that changes through the day

 

The Goulds e-SV series is available with the Hydrovar variable speed pump controller, which suits buildings where demand swings between a quiet night and a busy morning.

The Xylem Booster Pump Range From GENAVCO

1. Goulds e-SV Vertical Multistage Pumps

  • Confirmed specification: high efficiency multistage pump with a robust, long-life design, delivery up to 160 m3/h and head up to 330 m, available with the Hydrovar variable speed controller.
  • Application fit: building water supply, compounds and process boosting where a compact vertical footprint helps.

View Goulds e-SV vertical multistage pumps

2. Goulds e-MP Multistage Pumps

  • Confidential specification: horizontal or vertical orientation, discharge capacity of 600 m3/h, head capacity of 630 m, for boosting pressure, boiler feed, filtration, transportation and de-watering.
  • Suitable application: for large buildings, district system and industrial plant requiring high discharge capacity at high head pressure.

View Goulds e-MP multistage pumps

3. Goulds e-HM Horizontal Multistage Pumps

  • Confirmed specification: stainless steel horizontal multistage pumps with a compact, durable design, up to 15 percent more efficient.
  • Application fit: villas, small buildings and equipment boosting where space is limited.

View Goulds e-HM horizontal multistage pumps

4. Bell & Gossett e-80 Vertical Inline Pumps

  • Specified: Heavy duty close coupled inline pumps with maximum delivery of 565 m3/h and maximum head of 115 m.
  • Applicable for: Circulation and transfer applications that go straight into pipework, such as chilled and hot water circuits. Not applicable for high pressure boosting applications.

View Bell & Gossett vertical inline pumps

Low pressure on the top floors or a new building to supply?

Send us the building height, number of outlets, tank arrangement and the pressure you need at the highest point. We will size the booster set.

REQUEST A BOOSTER PUMP SIZING

Booster Pumps vs Other Pumps on the Same Site

The booster pump operates on water that is in the system. But filling up the system with water is another operation entirely, as pumping from a borehole, a sump, or a water tank requires submersible or transfer pumps depending on the position of the pump itself. For wet wells and sumps, see our guide to choosing a submersible pump impeller.

How to Specify a Booster Pump

Step 1 – Height between the pumping station and the highest point of outlet.

Step 2 – Outlets list and equipment list, along with the peak flow rate at which all operate together.

Step 3 – Pressure requirement for the highest or remotest point of the system.

Step 4 – Losses due to friction in pipes and fittings.

Step 5 – Pump duty, backup arrangement, and control of speed.

Step 6 - Confirm power supply and whether the set must run on standby power for critical building services.

Booster Pumps in UAE Buildings

  • Tank-fed buildings: UAE buildings use water tanks located either underground or on roofs; hence a booster set may be the only pressure supply to the floors it services.
  • High-rise peak demands: Peaks during the morning and evening time periods make variable speed control feasible in residential high-rises and hotels.
  • Heat in plant rooms: Plant rooms tend to get warm, hence ensure provision of adequate ventilation for motors and drives.
  • Water quality: Stainless steel pump materials used for the construction of pumps such as e-HM series have good corrosion resistance properties.

Why Choose GENAVCO for Booster Pumps

  • Xylem Goulds and Bell & Gossett ranges: vertical, horizontal and inline pumps from the Xylem family, so the booster set is matched to the building rather than to whatever pump is in stock. See Xylem Goulds water pumps and Bell & Gossett pumps.
  • Part of the Juma Al Majid Group since 1967: an established UAE supplier with ISO 9001 certification.
  • Service and genuine parts: certified technicians and genuine parts keep critical water supplies running. For more on how pumps fit into plant systems, read about compressors and pumps in industrial plants.

Common Booster Pump Mistakes

  • Sizing for average flow: the set must hold pressure at peak demand.
  • Forgetting friction losses: long pipe runs can cost as much pressure as several floors.
  • No standby pump: a single pump failure leaves the building without pressure.
  • Fixed speed on variable demand: pressure swings and higher energy use follow.
  • Running pumps dry: low-level protection in the suction tank prevents damage when supply runs short.

FAQs

What is the purpose of a booster pump?

To increase water pressure in buildings, compounds or factories in order to supply sufficient pressure to outlets and machinery, especially on upper levels or on the ends of long piping systems.

What distinguishes a booster pump from a regular pump?

Booster pumps are constructed to boost the pressure of existing water pressure and are multi-stage in order to provide high head. Transfer or submersible pumps move water from point to point like from a borehole/sump to a tank.

How do you size a booster pump for a building?

Calculate the total head required (height to the topmost discharge, losses due to friction, and pressure required at the topmost discharge), and maximum discharge rate from discharges available at one time. Then select the duty/standby pumps and controls.

Is a variable speed booster pump worth the cost?

If there is fluctuating demand during the day, then yes. Variable speed pumps, like Goulds e-SV pumps with Hydrovar controller, will maintain constant pressure and slow down when demand is low rather than turning on and off.

Need to Size your Booster Pump?

Booster pumps need to be sized depending on the height of the building, flow rate required and the pressure requirement of the highest point of the building. At GENAVCO, we provide you with Xylem Goulds Multistage Pumps and Bell & Gossett Inline Pumps in UAE.

Tell us your building height, outlets and tank arrangement. We will size the booster set and price it properly.

Serving Dubai, Abu Dhabi, Sharjah and the wider UAE.

REQUEST A BOOSTER PUMP SIZING

More Blogs

Hamm
02Jul

Soil Compactors and Plate Compactors: Key Differences Explained

Godrej
02Jul

How to Choose the Right Forklift for Warehouse Operations

Crown
02Jul

Why Pallet Racking Systems Are Essential for Modern Warehouses